Violet UVC Seoul Viosys LED Module 275nm 12 LEDs 152mW 29cm 48VDC IP67 with controler incl., for disinfection
- Highly efficient disinfection lamp with Violet UV-C LED module, designed for professional applications.
- Emits radiation with a 275nm wavelength to disinfect air, liquids, and surfaces effectively
- Capable of killing and inactivating bacteria, germs, and viruses, making it an indispensable tool for a wide range of industries
- Consists of top-quality components, including 12 Seoul Viosys UVC LEDs, PowerController V2 with DALI dimming and LED driver, silicone clear lens, and stainless steel metal frame, making it sturdy and durable
- Has an IP67 protection rating and is encased in a sturdy aluminum housing, making it suitable for even the toughest working conditions
- Compact design with dimensions of 297.3x44.6x32.8 mm (LxWXH), making it easy to install in a variety of settings
- Comes with a PowerController V2 for advanced dimming and safety features
- Constant voltage operation with 48VDC
- Comes with 3 signal LEDs (red, blue, and green) to indicate the lamp's status.
Our Violet UV-C LED module is a highly efficient disinfection lamp designed for professional applications. With its state-of-the-art technology, this lamp offers a reliable and effective solution for disinfecting air, liquids, and surfaces by emitting radiation with a 275nm wavelength. It is capable of killing and inactivating bacteria, germs, and viruses, making it an indispensable tool for a wide range of industries.
The Violet UV-C LED module is made in Germany with top-quality components, including 12 Seoul Viosys UVC LEDs with a UVC radiant flux of 270nm, providing a radiated power of 152mW when operating at a typical voltage of 48VDC. The module features a built-in Powercontroller V2 with DALI dimming and LED driver, which requires a 48VDC power supply. The UVC module also comes with a silicone clear lens and a stainless steel metal frame for a robust and durable build. The lens system has a wide beam of 52 degrees for each LED, ensuring maximum coverage.
With an IP67 protection rating, the Violet UV-C LED module is encased in a sturdy aluminum housing and can withstand even the toughest working conditions. It has a compact design with dimensions of 297.3x44.6x32.8 mm (LxWXH), making it easy to install in a variety of settings.
The Violet UV-C LED module comes with a PowerController V2 that allows for a combination of a button, switch, motion sensor, and three signal LEDs to ensure that the room is empty before activating the lamp. After the motion sensor detects no movement for 10 seconds, the button is activated by closing the door, and all safety conditions are fulfilled by a green signal LED. The UVC module can then be activated via the switch.
The Violet UV-C LED module is ideal for use in the industrial sector, including lighting manufacturers and companies in the medical technology sector. It is a powerful and efficient tool that ensures a safe and sterile environment, giving you peace of mind that your workspace is clean and hygienic.
The table below provides information on the surface irradiance with varying distances, giving you a clear idea of the coverage and effectiveness of the Violet UV-C LED module. With its advanced features and top-quality components, the Violet UV-C LED module is the perfect solution for your disinfection needs.
Features:
- LED module with 12 Seoul Viosys UVC LEDs (275nm)
- UVC radiant flux 270nm: 152mW at 48 VDC
- With built in Powercontroler V2 with DALI dimming and LED driver (48 VDC power supply required)
- Uses UVC rated lens for LEDIL, FN17294_VIOLET-12X1-S with 52 degree wide beam for each LED (available separately under article number 36480)
- Typical power consumption 12.72W at 48V
- Lens system made from silicone clear lens and stainless steel metal frame
- Robust aluminum housing
- UVC Module protection rating: IP67 (including lens)
- Dimensions: 297.3x44.6x32.8 mm (LxWXH)
- With included Powercontroler V2 from many dimming options
- Made in Germany
The table below illustrates the surface irradiance with varying distances.
Distance h [mm] |
Irradiation intensity E [mW/cm²] |
Simulation |
|
10 |
18.998 |
50 |
1.731 |
100 |
0.810 |
175 |
0.451 |
250 |
0.284 |
400 |
0.135 |
The following table* shows the irradiation time with a distance of 100 mm and an irradiation intensity of 0.81 mW/cm² on various microorganisms.
Microorganisms |
99.9% Dosage [mW * s cm²] |
Irradiation time |
Microorganisms |
99.9% Dosage [mW * s cm²] |
Irradiation time [s] |
|
Bacteria/ Viruses
|
Bakterium coli (in air) |
2.1 |
2.6 |
Proteus vulgaris |
7.8 |
9.6 |
Bakterium coli (in water) |
16.2
|
20 |
Pseudomonas aeruginosa |
16.5 |
20.4 |
|
Bacillus antharacis |
13.7 |
16.9 |
Pseudomonas fluorescens |
10.5 |
13 |
|
S. enteritidis |
12 |
14.8 |
S. tyyphimurium |
24 |
29.6 |
|
B. megatherium (veg.) |
3.4 |
4.2 |
Sarcina lutea |
59 |
72.8 |
|
B. megatherium sp. |
8 |
9.9 |
Serratia marcescens |
7.2 |
8.9 |
|
B. paratyphosus |
9.6 |
11.9 |
Dysentery bacilli |
6.6 |
8.1 |
|
13, prodiglosus |
2.1 |
2.6 |
Shigella paradysenteriae |
5.2 |
6.4 |
|
B. pyocyaneus |
13.2 |
16.3 |
Spirillum rubrurn |
13 |
16 |
|
B. subtilis spores |
36 |
44.4 |
Staphylococcus albus |
5.4 - 10 |
6.7 - 12.3 |
|
Cornynebacterium diphteriae |
10 |
12.3 |
Staphylococcus aureus |
6.6 - 14.8 |
8.2 - 18.3 |
|
Eberthella typhosa |
6.3 |
7.8 |
Streptococcus hemolyticus |
6.6 |
8.1 |
|
Escherichia coli |
9 |
11.1 |
Streptococcus lactis |
18 |
22.2 |
|
Legionella pneumophila |
2.76 |
3.4 |
Streptococcus viridans |
6 |
7.4 |
|
Micrococcus candidus |
19 |
23.5 |
Baccillus tuberculi |
30 |
37 |
|
Micrococcus piltonensis |
24 |
29.6 |
Trichonomas |
300 |
370.4 |
|
Micrococcus sphaeroides |
30 |
37 |
Poliovirus |
9.6 |
11.9 |
|
Neisseria catarrhalls |
13 |
16 |
Infectus Hepatitis |
17.4 |
21.5 |
|
Phytomonas tumefaciens |
13 |
16 |
Influenza |
10.2 |
12.6 |
|
-- |
- |
- |
Tobaco mosaic |
720 |
888.9 |
|
Yeasts |
Baker's yeast |
11.7 |
14.4 |
Saccharomyces spores |
24 |
29.6 |
Ale yeast |
9.9 |
12.2 |
Saccharomyces cerevisae |
186 |
22.2 |
|
Common baker's yeast |
18 |
22.2 |
Saccharomyces turpidans |
27 |
33.3 |
|
Saccharomyces ellipsoideus |
18 |
22.2 |
Torula sphaerica |
6.9 |
8.5 |
|
Moulds |
Aspergillus amstelodami |
200.1 |
247 |
Oospara lactis |
15 |
18.5 |
Aspergillus flavus |
180 |
222.2 |
Penicillium digitatum |
132 |
163 |
|
Aspergillus glaucus |
132 |
163 |
Penicillium expansum |
39 |
48.1 |
|
Aspergillus niger (Bakery) |
6396 |
488.9 |
Penicillium chrysogenum (Fruits) |
150 |
185.2 |
|
Cladosporium herbarum |
180 |
222.2 |
Penicillium roqueforti |
39 |
48.1 |
|
Mucur mucedol |
195 |
240.7 |
Rhizopus nigricans (Bread) |
333 |
411.1 |
|
Mucor racemodus A |
51 |
63 |
Scopulariopsis brevicaulis (Cheese, etc.) |
240 |
296.3 |
|
Mucor racemodus B |
51 |
63 |
- |
- |
- |
|
Algae |
Diatomeen |
1080 - 1800 |
1333.3 – 2222.2 |
Blue algae |
1080 - 1800 |
1333.3 – 2222.2 |
Green algae |
1080 - 1800 |
1333.3 – 2222.2 |
- |
- |
- |
|
Protozoa |
Paramecium |
192 - 300 |
237.1 – 370.4 |
- |
- |
- |
* The dosage stated in the table refers to a wavelength of 254 nm. The irradiation time was converted to the wavelength of this UVC module (275 nm) without taking the spectrum into account.
Note: This product is intended exclusively for customers who are trained in the use of UVC radiation and can ensure hazard-free use. Do you have further questions concerning this product or the topic UVC? Please send an e-mail to [email protected]
Warnings
- The article is a powerful UVC module which can be used for the disinfection of surfaces. It emits at a wavelength of 280 nm which is not visible to the human eye.
- It is imperative to ensure that users wear suitable protective clothing against UV radiation at all times. All skin and eye contact must be avoided.
- We recommend the use of the following protective agents:
- Safety goggles
- Gloves
- Face Shield
- Protective clothing that shields UV light from the skin
- Wear protective clothing at all times during use and ensure that no other persons are within reach of the radiation source without taking appropriate safety precautions.
- Light can reflect, therefore special precautions have to be taken with reflecting surfaces (e.g. mirrors).
- If skin tissue is exposed to the light source, skin irritation comparable to sunburn may occur. If necessary, treat the affected areas with a suitable cream or consult a physician.
- Low wavelength UV light can cause permanent damage to the retina in severe cases. Make sure to wear protective goggles at all times when using the device.
SKU | 36673 |
---|---|
Weight brut (g) | 610.000000 |
Color | UVC Ultraviolet |
Power (W) | 24 |
Warranty (months) | 10 |
Product lifetime (h) | 12000 |
Forward Current Max | 600 |
Wavelenght | 275 |
Manufacturer Product Code | 36673 UV-C |
Strip Type | Rigid |
LEDs number per sales unit | 12 |
Dimensions | 297x42x32.8 |
Dimensions: Length (cm) | 29.5 |
Dimensions: Width (mm) | 42 |
Dimensions: Height (mm) | 32.8 |
Brand | Lumistrips |
Forward Voltage Typ (V) | 23 |
Availability beyond shown stock: | YES |